The marine ethylene glycol heating system is mainly composed of a centrifugal pump, heat exchanger, pipeline valves and monitoring instruments, etc. The mixed liquid of ethylene glycol and water is used as the heat exchange medium, which is heated to the required temperature by the heat exchanger with the cooling liquid of the marine engine (mainly the jacket water), and then delivered to the back-end equipment. The centrifugal pump works for system circulation. Application and features 1. Compact structure and high degree of integration. 2. Low heat loss and high heat exchange efficiency. 3. Auxiliary electric heating, rapid warming in cold start. 4. Easy cleaning and long service life. Application:Applicable to the gas supply system of all kinds of vessels powered by natural gas.
Technical Specifications
Design Pressure | ≤1.6MPa | Temperature difference of inlet outlet | ≤10°C |
Design Temperature | -120℃〜90℃ | Design flow | Demanded |
Applicable Medium | Ethylene glycol, Water mixture |
|