The 70MPa hydrogen nozzle is provided with an automatic locking structure. After the nozzle head and the hydrogen port are connected in place, the internal jaws of the hydrogen nozzle automatically clamp the hydrogen port and lock it, which makes the hydr Technical Specificationsogen nozzle and the hydrogen port form a reliable mechanical connection. After the hydrogen nozzle successfully communicates with the vehicle-mounted system, press the hydrogen filling button on the hydrogen dispenser, and the high-pressure hydrogen flows to the vehicle-mounted steel cylinder at the back end of the hydrogen port through the hydrogen nozzle to fill hydrogen for the vehicle. After filling, the hydrogen nozzle will release the pressure of the gas inside the chamber of the hydrogen nozzle autonomously. After the pressure relief is completed, manually slide the outer sliding sleeve on the head of the hydrogen nozzle to separate the hydrogen nozzle from the hydrogen port and the whole filling process is completed.
Technical Specifications
Medium | H2 | Nominal Diameter | DN4 |
Medium Temperature | -40℃〜85℃ | Operating Temperature | -40℃〜85℃ |
Ambient Temperature | -40℃〜60℃ | Inlet Port Size | 9/16” -18UNF |
Nominal Diameter | DN8 | Explosion-proof grade | Ex ia ⅡC T4 Gb |
Relative humidity | ≤95% | Protection Rating | IP65 |
Rated Operating Pressure | 70MPa |
|